Customization: | Available |
---|---|
Transport Package: | Film,Wooded Case,Regular Seaworthy Packing,etc. |
Specification: | WPA-3000 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item/Model | Washing + Pelletizing + Patent + Chemical Addivitive | Washing + Pelletizing +SSP | ||
WPA-1000 | WPA-1500 | WPA-2000 | WPS | |
Capacity(kg/h) | 900-1100 | 1200-1800 | 1900-2500 | 800-2000 |
Required Area(m2) | 1800 | 2300 | 2300 | 2350-2550 |
Installation Power(kW) | 1300 | 1550 | 1700 | 1520-1820 |
Required Water(m3/hr) | 22.5 | 29.5 | 29.5 | 22.25-29.5 |
Chilling Water(m3/hr) | 20 | 25 | 25 | 50-75 |
Steam Consumption(kg/h) | 700 | 1300 | 1300 | 700-1300 |
Compressed Air(m3/min) | 700 | 1300 | 1300 | 700-1300 |
Nitrogen Consumption(Nm3/hr) | / | / | / | 40 |
Manpower(Nos.) | 7 | 9 | 9 | 7-10 |
Property | Unit | Design | Range |
Output Design capacity extrusion |
Kg/hour | Max.2200 | (based on 8000h/year) |
Output Design capacity SSP |
Kg/hour | 2000 | (based on 8424 h/year) |
Remarks to the difference in design capacities: Due to the more frequent maintenance intervals of the extruder compared to the SSP plant the extrusion capacity is higher than the SSP plant. |
|||
Minimal system capacity | % | 60 | min |
Utility | Unit | Expected Consumption | Installed |
Electrical power | [kW] | 578 | 808 |
Recirculation Cooling Water (30/38°C) |
[m3/h] | 30 | 40 |
Process Water (70/90°C) | [m3/h] | 30 | 40 |
Fresh Water/Treated water | [m3/h] | 0.2 | 0.5 |
Instrument air | [Nm3/h] | 5 | 6 |
Utility | Unit | Expected consumption | Installed |
Electrical power | [ kW] | 137 | 190 |
Nitrogen N2 | [Nm3/h] | 35 | 50 |
Natural Gas | [Therms/h] | 7.9 | 22 |
Instrument air | [Nm3/h] | 13 | 16 |
Compressed air | [Nm3/h] | hold | hold |
Chilled water circulation flow rate | [m3/h] | 20 | 30 |